<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-11 06-06-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
90.30 MHz 5/5, 63 dBuV VIBRA fm
Pilot RDS Phase Difference
6.6 kHz 3.5 kHz -65 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
9 kHz 72 kHz 17094 12,3201
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
6,7 dBr 7,68 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VIBRA fm" F560 9 (Varied) 1 0 1 1 --:--
RT
"VIBRATION - Vibrez avec nous "
AF EON
90.3, 93.1, 93.7, 97.7, 100.8, 101.7, 102.0 MHz -
FM Scope Station: 90.30 MHz, signal: 5/5 (63 dBuV) Max at: 72 kHz MIN: 9 kHz % above 75 kHz: 12,3201 Acquired: 2024/12/11 6:05:13 Total samples: 17094 Equivalent time: 0:14:14 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 8,4 dBr MIN: 6,7 dBr AVE: 7,68 dBr % above 13,0 dBr: 0,0 Last value: 8,0 dBr (2024/12/11 6:05:11) Station: 90.30 MHz, signal: 5/5 (63 dBuV) 05:52 05:54 05:56 05:58 06:00 06:02 06:04 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality